7 research outputs found

    Morphometric and Mechanical Analyses of Calcifications and Fibrous Plaque Tissue in Carotid Arteries for Plaque Rupture Risk Assessment

    Get PDF
    Objective: Atherosclerotic plaque rupture in carotid arteries is a major source of cerebrovascular events. Calcifications are highly prevalent in carotid plaques, but their role in plaque rupture remains poorly understood. This work studied the morphometric features of calcifications in carotid plaques and their effect on the stress distribution in the fibrous plaque tissue at the calcification interface, as a potential source of plaque rupture and clinical events. Methods: A comprehensive morphometric analysis of 65 histology cross-sections from 16 carotid plaques was performed to identify the morphology (size and shape) and location of plaque calcifications, and the fibrous-tissue fiber organization around them. Calcification-specific finite element models were constructed to examine the fibrous plaque tissue stresses at the calcification interface. Statistical correlation analysis was performed to elucidate the impact of calcification morphology and fibrous tissue organization on interface stresses. Results: Hundred-seventy-one calcifications were identified on the histology cross-sections, which showed great variation in morphology. Four distinct patterns of fiber organization in the plaque tissue were observed around the calcification. They were termed as attached, pushed-aside, encircling and random patterns. The stress analyses showed that calcifications are correlated with high interface stresses, which might be comparable to or even above the plaque strength. The stress levels depended on the calcification morphology and fiber organization. Thicker calcification with a circumferential slender shape, located close to the lumen were correlated most prominently to high interface stresses. Conclusion: Depending on its morphology and the fiber organization around it, a calcification in an atherosclerotic plaque can act as a stress riser and cause high interface stresses. Significance: This study demonstrated the potential of calcifications in atherosclerotic plaques to cause elevated stresses in plaque tissue and provided a biomechanical explanation for the histopathological findings of calcification-associated plaque rupture

    Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects

    Get PDF
    Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120-μm (titanium-120) or 230-μm (titanium-230) were studied in a load-bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium-120, titanium-230, or left empty. In vivo micro-CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm3(titanium-120, p = 0.015) and 18.7 ± 8.0 mm3(titanium-230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm3). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium-120) and 45% (titanium-230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects. Copyrigh

    Submicron patterns-on-a-chip: Fabrication of a microfluidic device incorporating 3D printed surface ornaments

    Get PDF
    Manufacturing high throughput in vitro models resembling the tissue microenvironment is highly demanded for studying bone regeneration. Tissues such as bone have complex multiscale architectures insid

    Mechanical factors explain development of cam-type deformity

    No full text
    Objective: A cam-type deformity drastically increases the risk of hip osteoarthritis (OA). Since this t

    Immunomodulation of surface biofunctionalized 3D printed porous titanium implants

    Get PDF
    Additive manufacturing (AM)techniques have provided many opportunities for the rational design of porous metallic biomaterials with complex and precisely controlled topologies that give rise to unprecedented combinations of mechanical, physical, and biological properties. These favorable properties can be enhanced by surface biofunctionalization to enable full tissue regeneration and minimize the risk of implant-associated infections(IAIs). There is, however, an increasing need to investigate the immune responses triggered by surface biofunctionalized AM porous metals. Here, we studied the immunomodulatory effects of AM porous titanium (Ti-6Al-4V) printed using selective laser melting, and of two additional groups consisting of AM implants surface biofunctionalized using plasma electrolytic oxidation (PEO)with/without silver nanoparticles. The responses of human primary macrophages and human mesenchymal stromal cells(hMSCs)were studied in terms of cell viability, cell morphology and biomarkers of macrophage polarization. Non-treated AM porous titanium triggered a strong pro-inflammatory response in macrophages, albeit combined with signs of anti-inflammatory effects. The PEO treatment of AM porous titanium implants showed a higher potential to induce polarization towards a pro-repair macrophage phenotype. We detected no cytotoxicity against hMSCs in any of the groups. However, the incorporation of silver nanoparticles resulted in strong cytotoxicity against attached macrophages. The results of this study indicate the potential immunomodulatory effects of the AM porous titanium enhanced with PEO treatment, and point towards caution and further research when using silver nanoparticles for preventing IAIs

    Global and Local Mechanical Properties and Microstructure of Friction Stir Welds with Dissimilar Materials and/or Thicknesses

    Get PDF
    This article studies the properties of a wide range of friction-stir-welded joints with dissimilar aluminum alloys or thicknesses. Two aluminum alloys, namely, 2024-T3 and 7075-T6, are selected for the study and are welded in ten different combinations of alloys and thicknesses. The welding parameters are optimized for each configuration, and a systematic study of the effects of material and thickness combinations on the microstructural features, global and local mechanical properties, and fracture mechanisms of the welds is carried out. It is shown that dissimilar alloys are extruded into each other, the texture is heterogeneous in the weld zone, and that there is no significant diffusion of alloying elements between the alloys. For most configurations, the local and global mechanical properties decrease as the thickness ratio increases. The local yield strength and plasticity parameters substantially vary next to the weld centerline, hence requiring their implementation in finite element method (FEM) models. Machining to obtain a constant thickness significantly influences the mechanical properties of the welds. The fracture mechanism is found to be a mixture of ductile and brittle fractures and to qualify as ‘‘quasi-cleavage.’’Materials Science and EngineeringMechanical, Maritime and Materials Engineerin

    Functionality-packed additively manufactured porous titanium implants

    Get PDF
    The holy grail of orthopedic implant design is to ward off both aseptic and septic loosening for long enough that the implant outlives the patient. Questing this holy grail is feasible only if orthopedic biomaterials possess a long list of functionalities that enable them to discharge the onerous task of permanently replacing the native bone tissue. Here, we present a rationally designed and additive manufacturing (AM) topologically ordered porous metallic biomaterial that is made from Ti-6Al-4V using selective laser melting and packs most (if not all) of the required functionalities into a single implant. In addition to presenting a fully interconnected porous structure and form-freedom that enables realization of patient-specific implants, the biomaterials developed here were biofunctionalized using plasma electrolytic oxidation to locally release both osteogenic (i.e. strontium) and antibacterial (i.e. silver ions) agents. The same single-step biofunctionalization process also incorporated hydroxyapatite into the surface of the implants. Our measurements verified the continued release of both types of active agents up to 28 days. Assessment of the antibacterial activity in vitro and in an ex vivo murine model demonstrat
    corecore